Product Information

SA-type Tank for concentrated sulfuric acid storage

Specifications

Liquid specific gravity 1.84g/㎤
Design pressure Atmospheric pressure
Design pressure Atmospheric pressure

Features

  • Polyethylene tank ideal for concentrated sulfuric acid storage.
  • Designed for safety and easy maintenance, tanks are reinforced by framing the entire body on all sides.
  • The liquid outlet nozzle is a heat fusion nozzle providing added safety.
  • Air vent ducts extend to the very bottom, improving overall safety.

Specifications (units: mm)

  • *DXF files may not be able to be displayed properly depending on the software used.
  • *1,000L~3,000L tank bodies utilize the SP type.

(L)
Outer diameter
(D)
Height of straight body part Total height Nozzle setting position at the top of tank Manhole at the top of tank Anchor hole Anchor bolts PCD Framed weight (kg) Notes Data
1,000 1,060 1,255 1,494 430 φ485 4×φ15 ≒1,110 ≒126 Standard SUS frame included
1,500 1,275 1,395 1,740 450 φ485 4×φ15 ≒1,325 ≒160 Standard SUS frame included
2,000 1,410 1,555 1,933 500 φ485 4×φ15 ≒1,460 ≒190 Standard SUS frame included
3,000 1,620 1,650 2,100 555 φ485 4×φ15 ≒1,670 ≒225 Standard SUS frame included
4,000 1,800 1,810 2,117 600 φ485 6×φ15 ≒1,850 ≒315 Standard SUS frame included
5,000 1,800 2,080 2,398 600 φ485 6×φ15 ≒1,850 ≒350 Standard SUS frame included
6,000 2,000 2,150 2,521 710 φ485 6×φ15 ≒2,050 ≒400 Standard SUS frame included
8,000 2,145 2,540 2,926 760 φ485 6×φ19 ≒2,205 ≒575 Standard SUS frame included
10,000 2,335 2,675 3,055 860 φ485 6×φ19 ≒2,395 ≒675 Standard SUS frame included
15,000 2,585 3,180 3,610 955 φ485 9×φ19 ≒2,645 ≒945 Standard SUS frame included
20,000 2,850 3,600 3,975 1,000 φ485 12×φ19 ≒2,910 ≒1,140 Standard SUS frame included
30,000 2,900 5,000 5,430 1,060 φ485 18×φ25 ≒2,980 ≒1,895 Standard SUS frame included
40,000 2,970 6,235 6,675 1,005 φ485 18×φ33 ≒3,060 ≒2,645 Standard SUS frame included
50,000 3,315 6,200 6,600 1,150 φ485 24×φ33 ≒3,405 ≒3,150 Standard SUS frame included

Caution!

After assembling and installing the tank and performing a water-filling test, please wipe down and completely remove all of the water used in the test. Also, make sure that no moisture remains on the tank. Any remaining water moisture may react with the sulfuric acid during filling to generate heat and potentially melting or damaging the tank.

Click here for other DXF/PDF data.