h Tank Lifetime Diagnostics|Dailite's Strengths|DAILITE Co., LTD

Dailite's Strengths

Tank Lifetime Diagnostics by FTIR (Fourier Transform Infrared Spectroscopy)

We perform diagnostic testing to confirm the degree of degradation on Dailite tanks that have been in use for an extended period of time.

At Dailite, we perform life diagnostics to measure the degree of oxidative degradation due to UV light on Dailite tanks that have been in use for an extended period of time. Our life diagnostics consist of a system our customers can reliably use that has been scientifically verified based on documents gathered by us over many years of operation. The methods for conducting measurements are incredibly simple. If you contact us with the number of tanks you would like examined, we will send you a special piece of sandpaper for sampling purposes. After receiving the returned sandpaper and sample, we will provide you with the results of our measurements as well as a diagnosis of your product's lifespan.

Degree of deterioration

Deterioration Degree of PE Resin, Infrared Spectrum

*The following graph (example) is for explanatory purposes. Please contact us for details.

  • Original graph

    Original graph

  • Measurement results graph (usage period of approximately 13 years)

    Measurement results graph
    (usage period of approximately 13 years)

  • Measurement results graph (usage period of approximately 25 years)

    Measurement results graph
    (usage period of approximately 25 years)